RELEASE 4.0 SYSTEM UTILITIES
19-6
Release 4.0
XC1000 Service
9 – Ports on Line Card 7
. Only ports on line card 7 are tested.
A – Ports on Line Card 8
. Only ports on line card 8 are tested.
B – Ports on Line Card 9
. Only ports on line card 9 are tested.
C – Ports on Line Card 10
. Only ports on line card 10 are tested.
D – Ports on Line Card 11
. Only ports on line card 11 are tested.
E – Ports on Line Card 12
. Only ports on line card 12 are tested.
F – Ports on Line Card 13
. Only ports on line card 13 are tested.
G – Ports on Line Card 14
. Only ports on line card 14 are tested.
H – Ports on Line Card 15
. Only ports on line card 15 are tested.
I – Ports on Line Card 16
. Only ports on line card 16 are tested.
J – Ports on Line Card 17
. Only ports on line card 17 are tested.
K – Ports on Line Card 18
. Only ports on line card 18 are tested.
Press the
SEND, Print Send
, or down-arrow key until the
Parameter
updated. Press any key to return to the Port Testing Menu.
prompt
appears.
19.2.1.2
Establishing Loopback-Testing Parameters.
Loopback testing is performed
to verify that the XC1000 can generate an outcall and detect that another voice
processor has received the outcall. The port being tested generates an autovon
“A” tone and listens for an autovon “A” tone in response. Perform the loopback
test either by having the XC1000 call a hunt group on the same XC1000 or
call a remote voice processor’s port or hunt group. Ports are tested randomly,
one at a time, until all ports are tested.
To establish loopback port-testing parameters, refer to Figure 19-4 and
complete the following fields, as described in section 19.2.1.1, with the
exceptions noted:
Port Testing Schedule 1
. Refer to section 19.2.1.1.
Port Testing Schedule 2
. Refer to section 19.2.1.1.
Maximum Time Allowable for Testing
. Refer to section 19.2.1.1.
Phone Number
. Enter the telephone number that the XC1000 will use
to place the test calls.
Dialing Sequence
. Enter the complete dialing sequence used to place
the test calls. The entry in this field must match the appropriate
dialing-sequence (local, long distance, international, or private network)
field entered in menu 6.1.
SA/NSA Alarm on Failure
. Refer to section 19.2.1.1.
Type of Test
. Enter
2 – Loopback Tes
t
.
Port Range
. Refer to section 19.2.1.1.
Press the
SEND, Print Send
, or down-arrow key until the
Parameter
updated. Press any key to return to the Port Testing Menu.
prompt
appears.
SECTION 19.2
Содержание XC1000
Страница 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Страница 8: ...CONTENTS ...
Страница 19: ...1 INTRODUCTION ...
Страница 30: ...2 SITE PREPARATION ...
Страница 60: ...3 PLATFORM INSTALLATION ...
Страница 112: ...4 STARTUP AND INITIALIZATION ...
Страница 177: ...5 ROUTINE MAINTENANCE ...
Страница 195: ...6 TROUBLESHOOTING ...
Страница 237: ...7 STATUS LOG ...
Страница 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Страница 302: ...8 REPAIR AND REPLACEMENT ...
Страница 380: ...9 SYSTEM UTILITIES ...
Страница 424: ...10 COMPONENT DESCRIPTIONS ...
Страница 465: ...11 OPTIONAL FEATURES ...
Страница 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Страница 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Страница 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Страница 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Страница 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Страница 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Страница 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Страница 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Страница 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Страница 787: ...APPENDIXES ...