![Octel XC1000 Скачать руководство пользователя страница 767](http://html.mh-extra.com/html/octel/xc1000/xc1000_service-manual_723818767.webp)
RELEASE 4.0 SYSTEM UTILITIES
19-5
Release 4.0
XC1000 Service
27 MAY 94 10:17:06AM
*** Possible Bad Port(s) Found during Port Testing – NSA
>>> INVESTIGATE SYSTEM ENVIRONMENT
00000 1CC00302 51010000 010006C9 7B530100
00010 0100EC07 00005243 50001700
Figure 19-5. Example of Status Code 151.
Figure 19-6 is an example of a status code generated by a service-
affecting alarm.
27 MAY 94 11:05:40AM
*** Possible Bad Port(s) Found during Port Testing – SA
>>> INVESTIGATE SYSTEM ENVIRONMENT
00000 1CC00202 52010000 010028F9 7B530100
00010 0100EC07 00005243 50001700
Figure 19-6. Example of Status Code 152.
When a port-test error (status code 151 or 152) is logged in the status
log, an outcalling error also is logged. Refer to the Review Previous
Test Results option in section 19.2.3 for details about port-test
failures. If additional information is necessary, analyze the outcalling
errors logged with the port-test error.
If a port-test error (status code 151 or 152) is logged in the status log
and there is no accompanying outcalling error, verify that the Port
Testing Administration screen (Figure 19-4) was configured correctly,
and run the test again. It is possible that a configuration problem in
the Port Testing Administration screen caused a repeated busy or
ring-no-answer situation on the port being tested.
Type of Test
. Enter
1 – Dial Tone Detect
.
Port Range
. Enter the ports to be tested. Enter one of the following
values:
1 – All Ports.
All available ports are tested. A port is available
whenever there is a
Y
for that port in
any
column in menu 4.
2 – Outcall Ports Only
. Only ports with a
Y
in the
O
(outcalling)
column in menu 4 are tested.
3 – Ports on Line Card 1
. Only ports on line card 1 are tested.
4 – Ports on Line Card 2
. Only ports on line card 2 are tested.
5 – Ports on Line Card 3
. Only ports on line card 3 are tested.
6 – Ports on Line Card 4
. Only ports on line card 4 are tested.
7 – Ports on Line Card 5
. Only ports on line card 5 are tested.
8 – Ports on Line Card 6
. Only ports on line card 6 are tested.
SECTION 19.2
Содержание XC1000
Страница 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Страница 8: ...CONTENTS ...
Страница 19: ...1 INTRODUCTION ...
Страница 30: ...2 SITE PREPARATION ...
Страница 60: ...3 PLATFORM INSTALLATION ...
Страница 112: ...4 STARTUP AND INITIALIZATION ...
Страница 177: ...5 ROUTINE MAINTENANCE ...
Страница 195: ...6 TROUBLESHOOTING ...
Страница 237: ...7 STATUS LOG ...
Страница 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Страница 302: ...8 REPAIR AND REPLACEMENT ...
Страница 380: ...9 SYSTEM UTILITIES ...
Страница 424: ...10 COMPONENT DESCRIPTIONS ...
Страница 465: ...11 OPTIONAL FEATURES ...
Страница 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Страница 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Страница 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Страница 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Страница 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Страница 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Страница 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Страница 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Страница 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Страница 787: ...APPENDIXES ...