![Octel XC1000 Скачать руководство пользователя страница 754](http://html.mh-extra.com/html/octel/xc1000/xc1000_service-manual_723818754.webp)
RELEASE 4.X ONLINE UPGRADE INSTRUCTIONS
18-25
Release 4.X
XC1000 Service
18.15 DISABLE THE ENGINEERING BIT
Call the Octel TAC to have the engineering bit turned off.
18.16 MAKE SOFTWARE AND PHRASE AREAS
REDUNDANT
Release 3.0 introduced multiple software areas to the XC1000 to allow an
upgrade to be performed online and to allow new software releases to be
run on a trial basis, with the option of returning to the previous release.
The XC1000 should now be running at new software Release 4.X, with the
prior release in the nonboot area. Octel recommends that you run the
XC1000 on the new software for approximately 1 week to be sure that it
runs smoothly before you make areas A and B redundant.
If the XC1000 runs smoothly with software Release 4.X, make software
areas redundant as follows:
1. Call the Octel TAC to have the service bit turned on. Be prepared to
provide the pilot number of the hunt group assigned to the XC1000.
Wait for confirmation that the service bit has been turned on.
2. At the SMT Main Menu prompt, type
20
and press
Return
to select
Menu 20 – Service Operations.
3. Type the number for the
Drive Copy Utilities
option and press
Return
.
4. Type the number for the
Make Drive(s) Redundant
option and press
Return
.
5. Type the number for the
Make Software Areas A and B Redundant
option and press
Return
.
6. The current
System Boot Area:
and
Drive Next Boot Area:
fields are
displayed, along with software versions of the two areas. At
Make
Software area [destination] a redundant copy of area [source]?
(y/n):
, type
y
and press
Return
to make the software areas redundant.
7. At
Software areas now redundant...Press any key to continue
,
type
^C
.
8. Type the number for the
Make Phrase Areas A and B Redundant
option and press
Return
.
9. The current
System Boot Area:
and
Drive Next Boot Area:
fields are
displayed, along with phrase versions of the two areas. At
Make
Phrase area [destination] a redundant copy of area [source]?
(y/n):
, type
y
and press
Return
to make the phrase areas redundant.
10. At
Phrase areas now redundant...Press any key to continue
, type
^C
three times to return to the SMT Main Menu.
11. Call the Octel TAC to have the service bit turned off.
SECTION 18.15 – 18.16
Содержание XC1000
Страница 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Страница 8: ...CONTENTS ...
Страница 19: ...1 INTRODUCTION ...
Страница 30: ...2 SITE PREPARATION ...
Страница 60: ...3 PLATFORM INSTALLATION ...
Страница 112: ...4 STARTUP AND INITIALIZATION ...
Страница 177: ...5 ROUTINE MAINTENANCE ...
Страница 195: ...6 TROUBLESHOOTING ...
Страница 237: ...7 STATUS LOG ...
Страница 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Страница 302: ...8 REPAIR AND REPLACEMENT ...
Страница 380: ...9 SYSTEM UTILITIES ...
Страница 424: ...10 COMPONENT DESCRIPTIONS ...
Страница 465: ...11 OPTIONAL FEATURES ...
Страница 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Страница 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Страница 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Страница 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Страница 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Страница 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Страница 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Страница 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Страница 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Страница 787: ...APPENDIXES ...