User Manual Of EL7-EC** AC Servo
123
E-STOP
Reserve
d
Reserve
d
Reserve
d
Reserve
d
Reserve
d
DI14
DI13
Bit15
Bit14
Bit13
Bit12
Bit11
Bit10
Bit9
Bit8
DI12
DI11
DI10
DI9
DI8
DI7
DI6
DI5
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
DI4
DI3
DI2
DI1
Reserve
d
HOME
POT
NOT
Index
60FEh-01
Label
Output valid
Unit -
Structure
VAR
Type
UInt 32
Access
RW
Mapping RPDO Mode F
Range
0x0~0x7FF
FFFFF
Default 0x0
The bits of 60FEh object are functionally defined as follow:
Bit
Sub-index
31~21
21
20
19
18
17
16
15~0
01h
Reserv
ed
DO6 valid DO5 valid DO4 valid DO3 valid
DO2 valid
DO1 valid
Reserve
d
Index
60FEh-0
2
Label
Output enabled
Unit
-
Structur
e
VAR
Type
UInt 32
Access
R
W
Mapping RPDO Mode F
Range
0x0~0x7FFFFFF
F
Defaul
t
0xFFFF0
000
The bits of a 60FEh object are functionally defined as follow:
Bit
Sub-index
31~21
21
20
19
18
17
16
15~0
02h
Reserve
d
DO6
enabled
DO5
enabled
DO4
enabled
DO3
enabled
DO2
enabled
DO1
enabled
Reserve
d
Index
60FFh
Label
Target velocity
Unit
Comman
d unit
Structure
VAR
Type
Int 32
Access RW Mapping RPDO Mode CSV/PV
Range
-2147483647
~2147483647
Default 0
Shows set target velocity. Limited by 6080h
Index
6502h
Label
Supported operation
modes
Unit
-
Structure
VAR
Type
UInt 32
Acces
s
R0
Mapping TPDO Mode F
Range
0x0~0x7FFFF
FFF
Defaul
t
0x0
Shows the control modes supported by the servo drive.