User Manual Of EL7-EC** AC Servo
197
Mode 26
:
This mode is similar to mode 10. Only difference is that homing point detection is not
through Z-signal but through triggering of homing switch signal
Z-signal
HOMING SWITCH
B:
HOMING SWITCH=ON
POT=OFF
Positive limit
POT
A:
HOMING SWITCH=OFF
POT=OFF
C:
HOMING SWITCH=OFF
POT=OFF
High Velocity
6099h-01h
Low Velocity
6099h-02h
Start
Stop
26
26
26
Mode 27
:
This mode is similar to mode 11. Only difference is that homing point detection is not
through Z-signal but through triggering of homing switch signal
Z-Signal
HOMING SWITCH
B:
HOMING SWITCH=ON
NOT=OFF
Negative limit
NOT
A:
HOMING SWITCH=OFF
NOT=OFF
C:
HOMING SWITCH=OFF
NOT=OFF
High Velocity
6099h-01h
Low Velocity
6099h-02h
Start
Stop
27
27
27