User Manual Of EL7-EC** AC Servo
64
recommended for load mounted vertical to ground, or
please compensate for the load using Pr6.07
0x0_0 Load type
setting
Used to select the load type, choose according to load-inertia ratio and
mechanical structure.
0: Rigid
structure
This mode prioritizes system responsiveness. Use this
mode when there is a relatively rigid structure with low
load inertia. Typical application including directly
connected high-precision gearbox, lead screw, gears,
etc.
1:High inertia
For applications with higher load inertia (10 times or
above), gain settings take into account both machine
stability and responsiveness. Not recommended to set
stiffness above 15 for high load inertia.
2: Flexible
structure
This mode prioritizes system stability. Use this mode
when there is low rigidity structure with high load
inertia. Typical applications included belts and chains.
0x_00 reserved
The setting type combination is a hexadecimal standard, as follows:
Setting type
combination
Application type
0X000
Rigid structure Manual
0X001
Rigid strStandard
0X002
Rigid strPositioning
0X010
High i Manual
0X011
High i Standard
0X012
High i Positioning
0X020
Flexible str Manual
0X021
Flexible structure
+Standard
0X022
Flexible structure
+Positioning