User Manual Of EL7-EC** AC Servo
216
2: Flexible
structure
This mode prioritizes system stability. Use this mode
when there is low rigidity structure with high load
inertia. Typical applications included belts and chains.
0x_00 reserved
The setting type combination is a hexadecimal standard, as follows:
Setting type
combination
Application type
0X000
Rigid structure Manual
0X001
Rigid strStandard
0X002
Rigid strPositioning
0X010
High i Manual
0X011
High i Standard
0X012
High i Positioning
0X020
Flexible str Manual
0X021
Flexible structure
+Standard
0X022
Flexible structure
+Positioning
Pr0.03
Name
Real time auto stiffness
adjusting
Mode
F
Range
50 ~ 81
Unit
—
Default
70
Index
2003h
Activation
Immediate
Valid when Pr0.03 = 1,2
Low
High
Mechanical stiffness
Servo gain
Responsiveness
81.80
……………………………
70.69.68
…………………………
51.50
High
High
Low
Low
Lower values ensure better system responsiveness and mechanical stiffness but machine