User Manual Of EL7-EC** AC Servo
96
Pr5.01
Label
2
nd
Command frequency
divider/multiplier
numerator
Mode
F
Range
0~1073741824 Unit
-
Default
1
Index
2501h
Activation
After restart
To set the numerator of command pulse input frequency divider/multiplier.
Pr5.02
Label
2
nd
Command frequency
divider/multiplier
denominator
Mode
F
Range
0~1073741824 Unit
-
Default
1
Index
2502h
Activation
After restart
To set the denominator of command pulse input frequency divider/multiplier.
Pr5.04
Label
Driver prohibition input
settings
Mode
F
Range
0~2
Unit
—
Defaul
t
0 Index
2504h
Activation
Immediate
To set driver prohibition input (POT/NOT): If set to 1, no effect on homing mode.
Set value
Explanation
0
POT
Positive direction drive prohibited
NOT
Negative direction drive prohibited
1
POT and NOT invalid
2
Any single sided input from POT or NOT might cause Er260
In homing mode, POT/NOT invalid, please set object dictionary 5012-04 bit0=1
Pr5.06
Label
Servo-off mode
Mode
F
Range
0~5
Unit
—
Default
0
Index
2506h
Activation
After restart
To set servo driver disable mode and status.
Set value
Explanation
Mode
Status
0
Servo braking
Dynamic braking
1
Free stopping
Dynamic braking
2
Dynamic braking
Dynamic braking
3
Servo braking
Free-run
4
Free stopping
Free-run
5
Dynamic braking
Free-run