3.1 Parameter List
Panel Display as follows:
Parameter Valid mode Description
CSP: Valid in cyclic synchronous position mode
CSV: Valid in cyclic synchronous velocity mode
CST: Valid in cyclic synchronous torque mode
HM: Valid in homing mode
PP: Valid in profile position mode
PV: Valid in profile velocity mode
PT: Valid in profile torque mode
F: Valid in all modes
3.1.1 Servo drive parameters
Class
Label
EtherCAT
Address
Panel
display
Activation
Valid Mode
[C
la
ss
0
] Bas
ic
se
tti
ng
s
Model-following
bandwidth
2000h
PR_000
Immediate
F
Control Mode Settings
2001h
PR_001
After restart
F
Real time Auto Gain
Adjusting
2002h
PR_002
Immediate
F
Real time auto stiffness
adjusting
2003h
PR_003
Immediate
F
Inertia ratio
2004h
PR_004
Immediate
F
Command polarity
inversion
2006h
PR_006
After restart
F
Probe signal polarity
settings/Command pulse
input mode settings
2007h
PR_007
After restart
F
Command pulse counts
per revolution
2008h
PR_008
After restart
PP PV
H
M
CSP CSV
Encoder pulse output per
revolution
2011
PR_011
After restart
F
Pulse output logic
2012
PR_012
After restart
F