User Manual Of EL7-EC** AC Servo
77
0
Activation
Immediate
To eliminate the instability of gain switching. Used in combination with Pr1.17 using the same unit.
If level< hysteresis, drive will set internally hysteresis = level.
Pr1.19
Label
Position gain switching
time
Mode
F
Range
0~10000 Unit
0.1ms Default
33
Index
2119h
Activation
Immediate
During position control, to ease torque changes and vibration due to rapid changes in position
loop gain, set suitable Pr1.19 value
For example: 1
st
(pr1.00) <-> 2nd (Pr1.05)
Pr1.35
Label
Position command pulse
filter time
Mode
F
Range
0~200
Unit
20ns Default
20
Index
2135h
Activation
Immediate
To eliminate interfering narrow band pulse train from position command pulse.
If value set is too high, it might interfere high frequency position command pulse receiving and
causes large delays.
Pr1.35 calculation formula: