Homing mode
Torque limiting mode
Mode-6
:
Search for homing point in negative direction at low velocity. Stop after torque
reaches the value set in Pr5.39 and homing done signal delivers after the time value set
in Pr5.37
Low velocity
6099h-02h
Start
Stop
-6
Mode -5
:
Search for homing point in positive direction at low velocity. Stop after torque
reaches the value set in Pr5.39 and homing done signal delivers after the time value set
in Pr5.37
Low velocity
6099h-02h
Start
Stop
-5
Mode -4
:
Search for homing point in negative direction at high velocity. Move in positive
direction after torque reaches the value set in Pr5.39, stops when torque is gone.
Homing done signal delivers after the time value set in Pr5.37
High velocity
6099h-01h
Low velocity
6099h-02h
Start
Stop
-4