User Manual Of EL7-EC** AC Servo
118
Index
6099h-02
Label
Low speed homing
Unit
Command
unit/s
Structure
VAR
Type
UInt 32
Access
R
W
Mapping
RPDO Mode HM
Range
0~214
74836
47
Default 5000
To set the speed used in homing
Index
609Ah
Label
Homing
acceleration
/deceleration
Unit
Command
unit/s²
Structure
VAR
Type
UInt 32
Access
R
0
Mapping
TPDO Mode HM
Range
1~2147
48364
7
Default 500000
To set acceleration and deceleration used in homing
Index
60B0h
Label
Position feedforward Unit
Command
unit
Structure
VAR
Type
Int 32
Access
R
0
Mapping
TPDO Mode HM
Range
-214748364
7~21474836
47
Default
0
To add position deviation to target position
Index
60B1h
Label
Velocity feedforward Unit
Command
unit/s
Structure
VAR
Type
Int 32
Access
R
0
Mapping
TPDO Mode
CSP/CSV/PP
/PV/HM
Range
-214748364
7~21474836
47
Default
0
To deviate velocity command
Index
60B2h
Label
Torque feedforward
Unit 0.1%
Structure
VAR
Type
Int 16
Access
R
W
Mapping
RPDO Mode
CSP/CSV/PP
/PV/HM
Range
0x0~0xFFF
F
Default
0x0
To add or deviate torque command