User Manual Of EL7-EC** AC Servo
78
3.2.3
【
Class 2
】
Vibration Suppression
Pr2.00
Label
Adaptive filtering mode
settings
Mode
F
Range
0~4
Unit
-
Default
0
Index
2200h
Activation
Immediate
Set value
Explanation
0
Adaptive filter: invalid
Parameters related to 3
rd
and 4
th
notch filter
remain unchanged
1
Adaptive filter: 1 filter
valid for once.
1 adaptive filter becomes valid. 3
rd
notch filter
related parameters updated accordingly.
Pr2.00 switches automatically to 0 once
updated.
2
Adaptive filter: 1 filter
remains valid
1 adaptive filter becomes valid. 3
rd
notch filter
related parameters will keep updating
accordingly.
3-4
Reserved
-
Pr2.01
Label
1
st
notch frequency
Mode
F
Range
50~40
00
Unit
Hz Default
4000
Index
2201h
Activation
Immediate
Set center frequency of 1
st
torque command notch filter.
Set Pr2.01 to 4000 to deactivate notch filter
Pr2.02
Label
1
st
notch bandwidth
selection
Mode
F
Range
0~20
Unit
-
Default
4
Index
2202h
Activation
Immediate
Set notch bandwidth for 1
st
resonant notch filter.
Under normal circumstances, please use factory default settings. If resonance is under control,
in combination with Pr2.01 and Pr2.03, Pr2.02 can be reduced to improve current loop
responsiveness which allows higher mechanical stiffness settings.
Pr2.03
Label
1
st
notch depth selection
Mode
F
Range
0~99
Unit
-
Default
0
Index
2203h
Activation
Immediate