User Manual Of EL7-EC** AC Servo
83
Pr2.35
Label
6
th
resonant frequency
Mode
F
Range
50~400
0
Unit
Hz
Default
4000
Index
2235h
Activation
Immediate
To set zero-valued eigenfrequency of 6
th
resonant notch filter. Pr2.35 corresponds to
machine-specific resonant frequency.
Notch filter deactivated if Pr2.31 is set to any value.
Pr2.36
Label
6
th
resonant Q value
Mode
F
Range
0~10000 Unit
Hz
Default
0
Index
2236h
Activation
Immediate
To set notch Q value of 6
th
resonant notch filter
Pr2.37
Label
6
th
anti-resonant
frequency
Mode
F
Range
50~4000
0
Unit
Hz
Default
4000
Index
2237h
Activation
Immediate
To set zero-valued eigenfrequency of 6
th
resonant notch filter. Pr2.37 corresponds to
machine-specific anti-resonant frequency.
Pr2.38
Label
6
th
anti-resonant Q value
Mode
F
Range
0~9900
Unit
Hz
Default
0
Index
2238h
Activation
Immediate
To set resonant Q value of 6
th
resonant notch filter
3.2.4
【
Class 3
】
Velocity/ Torque Control
Pr3.00
Label
Internal/External settings
of velocity settings
Mode
F
Range
0~3
Unit
-
Default
1
Index
2300h
Activation
Immediate
Internal
velocity
settings can be achieved by connecting to driver’s input interface.
Set value
Velocity settings
0
Analog velocity command (SPR)
[1]
Internal velocity command: 1
st
to 4
th
speed (Pr3.04 to Pr3.07)
2
Internal velocity command 1
st
to 3
rd
speed (Pr3.04 to Pr3.06),