User Manual Of EL7-EC** AC Servo
111
Index
6064h
Label
Actual position
feedback
Unit
Comman
d unit
Structure
VAR
Type
Int 32
Access
R
0
Mapping TPDO Mode F
Range
-21474836
48~214748
3647
Default 0
Reflects user’s real time absolute position
6064h*Gear ratio = 6063h
Index
6065h
Label
Position deviation
window
Unit
Comman
d unit
Structure
VAR
Type
UInt
32
Access
R
0
Mapping TPDO Mode
PP/CSP/
HM
Range
0~2147483
647
Default 0
To set an acceptable deviation for requested position.
When actual position exceed position deviation window, error might occur.
Index
6066h
Label
Position deviation
detection time
Unit ms
Structure
VAR
Type
UInt 16
Access
R
0
Mapping TPDO Mode
PP/CSP/
HM
Range
0~65535
Default 0
To set position deviation detection time
Index
6067h
Label
Position window
Unit
Comman
d unit/s
Structure
VAR
Type
UInt
32
Access
R
0
Mapping TPDO Mode
PP/CSP/
HM
Range
0~2147483
647
Default 0
To set an acceptable extent of arrival position
Index
6068h
Label
Position window
time
Unit
Comman
d unit/s
Structure
VAR
Type
UInt 16
Access
R
0
Mapping TPDO Mode
PP/CSP/
HM
Range
0~65535
Default 0
To set the time between arrival to the output of INP (In position) signal.
Index
606Bh
Label
Internal command
velocity
Unit
Comman
d unit/s
Structure
VAR
Type
Int 32
Access
R
0
Mapping TPDO Mode ALL
Range
-21474836
48~214748
3647
Default 0