User Manual Of EL7-EC** AC Servo
121
Index
60C5h
Label
Protocol maximum
acceleration
Unit
Command
unit/s²
Structure
VAR
Type
UInt 32
Access
R
W
Mapping
RPDO Mode F
Range
1~21474836
47
Default
1000000
00
To set upper limit of acceleration.
Index
60C6h
Label
Protocol maximum
deceleration
Unit
Command
unit/s²
Structure
VAR
Type
UInt 32
Access
R
W
Mapping
RPDO Mode F
Range
1~21474836
47
Default
1000000
00
To set lower limit of acceleration.
Index
60D5h
Label
Probe 1 rising edge
captured count(s)
Unit
-
Structure
VAR
Type
UInt 16
Access
R0
Mapping TPDO
Mode F
Range
0~65535
Default 0
Shows the number of times probe 1 rising edge latched.
Index
60D6h
Label
Probe 1 falling edge
captured count(s)
Unit -
Structure
VAR
Type
UInt 16
Access
R0
Mapping TPDO
Mode F
Range
0~65535
Default 0
Shows the number of times probe 1 falling edge latched.
Index
60D7h
Label
Probe 2 rising edge
captured count(s)
Unit
-
Structure
VAR
Type
UInt 16
Access R0
Mapping TPDO
Mode F
Range
0~65535
Default 0
Shows the number of times probe 2 rising edge latched.
Index
60D8h
Label
Probe 2 falling edge
captured count(s)
Unit -
Structure
VAR
Type
UInt 16
Access R0
Mapping TPDO
Mode F
Range
0~65535
Default 0
Shows the number of times probe 2 falling edge latched.
47
Shows position feedback at falling edge of probe 2 signal