User Manual Of EL7-EC** AC Servo
108
2
:
Motor decelerates and stops through 6085. Status: Switch on disable, axis disabled.
3
:
Motor decelerates and stops through 60C6. Status: Switch on disable, axis disabled.
5
:
Motor decelerates and stops through 6084. Status: Quick stop
6
:
Motor decelerates and stops through 6085. Status: Quick stop
7
:
Motor decelerates and stops through 60C6. Status: Quick stop
HM
0
:
To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1
:
Motor decelerates and stops through 609A. Status: Switch on disable, axis disabled.
2
:
Motor decelerates and stops through 6085. Status: Switch on disable, axis disabled.
3
:
Motor decelerates and stops through 60C6. Status: Switch on disable, axis disabled.
5
:
Motor decelerates and stops through 609A. Status: Quick stop
6
:
Motor decelerates and stops through 6085. Status: Quick stop
7
:
Motor decelerates and stops through 60C6. Status: Quick stop
CST
0
:
To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1, 2
:
Motor decelerates and stops through 6087. Status: Switch on disable, axis disabled.
3
:
Motor decelerates and stops through torque = 0. Status: Switch on disable, axis disabled.
5, 6
:
Motor decelerates and stops through 6087. Status: Quick stop
7
:
Motor decelerates and stops through torque = 0. Status: Quick stop
Index
605Bh
Label
Motor deceleration-stopping
mode selection
Mode
F
Range
RW
Unit
-
Range
0~1
Default
0
PP, CSP, CSV, PV
0
:
To stop motor through Pr5.06, 5.06 = 0(Emergency stop), 5.06=1(Free stop)
1
:
Motor decelerates and stops through 6084
HM
0
:
To stop motor through Pr5.06, 5.06 = 0(Emergency stop), 5.06=1(Free stop)
1
:
Motor decelerates and stops through 609A
CST
0
:
To stop motor through Pr5.06, 5.06 = 0(Emergency stop), 5.06=1(Free stop)
1
:
Motor decelerates and stops through 6087
Index
605Ch
Label
Axis disabled-stopping mode
selection
Mode
F
Range
RW
Unit
-
Range
0~1
Default
0
PP, CSP, CSV, PV
0
:
To stop motor through Pr5.06, 5.06 = 0(Emergency stop), 5.06=1(Free stop)
1
:
Motor decelerates and stops through 6084
HM
0
:
To stop motor through Pr5.06, 5.06 = 0(Emergency stop), 5.06=1(Free stop)