User Manual Of EL7-EC** AC Servo
88
Pr3.15
Label
Zero speed clamp function
selection
Mode
F
Range
0~3
Unit
-
Default
0
Index
2315h
Activation
Immediate
Set
value
Zero speed clamp function
0
Invalid: zero speed clamp deactivated
1
Velocity command is forced to 0 when the zero speed clamp (ZEROSPD) input
signal is valid.
2
Velocity command is forced to 0 when actual velocity is lower than Pr3.16.
3
Includes conditions from 1 and 2
Pr3.16
Label
Zero speed clamp level
Mode
PV
CSV
Range
10~2000
Unit
RPM
Default
30
Index
2316h
Activation
Immediate
Velocity command is forced to 0 when actual velocity is lower than Pr3.16 and after static time set
in Pr3.23
Pr3.17
Label
Internal/External settings
of torque
Mode
F
Range
0~3
Unit
-
Default
0
Index
2317h
Activation
Immediate
Set
value
Torque command input
Velocity limit input
0
Analog input 3
(AI3)
Parameter value
(Pr3.21)
1
Analog input 3
(AI3)
Analog input 1
(AI1)
2
Parameter value
(Pr3.22)
Parameter value
(Pr3.21)
3
Analog 1 is set by 485
Analog 3 is set by 485
Pr3.18
Label
Torque command direction
selection
Mode
PT
CS
T
Range
0~1
Unit
-
Default
0
Index
2318h
Activation