User Manual Of EL7-EC** AC Servo
57
Class
Label
EtherCAT
Address
Panel
display
Activation
Valid Mode
A
bsolute value rotation
mode denominator setting
2654h
PR_654
After restart
PP
H
M
CSP
Blocked rotor alarm
torque threshold
2656h
PR_656
Immediate
F
Blocked rotor alarm
delay time
2657h
PR_657
Immediate
F
Homing mode position
threshold
2659h
PR_659
Immediate
F
Z signal holding time
2661h
PR_661
Immediate
F
Absolute multiturn data
upper limit
2663h
PR_663
After restart
F
3.1.2 Manufacturer parameters
Index
Sub
index
Label
Unit
Default
Min
Max
Details
5004
01
RPDO length
8
0
64
02
TPDO length
17
0
64
03
The number of
RPDO
1
0
4
04
The number of
TPDO
1
0
2
05
Sync0 Watchdog
counter
0
0
65535
06
Reserved
0
65535
07
Sync0 Watchdog
limit
4
0
65535 73B alarm threshold value, set
to zero shield
08
Sync0 Drift
watchdog counter
0
0
65535
09
Sync0 Drift
watchdog limit
4
0
65535 73C alarm threshold value, set
to zero shield
0A
SM2 watchdog
counter
0
0
65535
0B
SM2 Watchdog
limit
4
0
65535 73A alarm threshold value, set
to zero shield
0C
Application layer
SM2/Sync0
watchdog counter
0
0D
Application layer
SM2/Sync0
watchdog limit
4
0E
Reserved
0
500
0F
Time interval
between SM2 and
Sync0
ns
0
0
100000
0000 832h Alarm detection
5006
00
Synchronous
alarm setting
0xFFF
F
0
0xFFF
F
Bit0:818h Alarm enable switch
Bit1: 819h