User Manual Of EL7-EC** AC Servo
119
Index
60B8h
Label
Probe function
Unit
-
Structure
VAR
Type
UInt 16
Access
RW
Mapping RPDO Mode F
Range
0x0-0xFFF
F
Default 0x0
Bit
Description
Details
0
Probe 1
0--Disable
1--Enable
1
Probe 1 trigger mode
0--Single trigger, triggered only when trigger
signal is valid
1—Continuous trigger
2
Probe 1 trigger signal selection 0—Probe 1 captured
1--Z signal
3
Reserved
-
4
Probe 1 rising edge enabled
0--Disable
1--Enable
5
Probe 1 falling edge enabled
0--Disable
1--Enable
6-7
Reserved
-
8
Probe 2
0--Disable
1--Enable
9
Probe 2 trigger mode
0--Single trigger, triggered only when trigger
signal is valid
1—Continuous trigger
10
Probe 2 trigger signal
selection
0—Probe 2 captured
1--Z signal
11
Reserved
-
12
Probe 2 rising edge enabled
0—Rising edge not latched
1—Rising edge latched
13
Probe 2 falling edge enabled
0—Falling edge not latched
1—Falling edge latched
14-15
Reserved
-