User Manual Of EL7-EC** AC Servo
90
3.2.5
【
Class 4
】
I/O Interface Setting
Pr4.00
Label
Input selection DI1
Mode
F
Range
0x0~0xFF Unit
—
Default
0x0
Index
2400h
Activation
Immediate
Pr4.01
Label
Input selection DI2
Mode
F
Range
0x0~0xFF Unit
—
Default
0x1
Index
2401h
Activation
Immediate
Pr4.02
Label
Input selection DI3
Mode
F
Range
0x0~0xFF Unit
—
Default
0x2
Index
2402h
Activation
Immediate
Pr4.03
Label
Input selection DI4
Mode
F
Range
0x0~0xFF Unit
—
Default
0x16
Index
2403h
Activation
Immediate
Digital input DI allocation using hexadecimal system
Input
Symbol
Set value
0x60FD
(bit)
Normally
open
Normally
close
Invalid
—
0h
-
×
Positive limit switch
POT
1h
81h
Bit1
Negative limit switch
NOT
2h
82h
Bit0
Servo on
SRV-ON
3h
83h
×
Clear alarm
A-CLR
4h
-
×
Control mode switching
C-MODE
5h
85h
×
Gain switching
GAIN
6h
86h
×
Clear deviation counter
CL
7h
-
×
Command pulse inhibition
INH
8h
88h
×
Torque limit switching
TL-SEL
9h
89h
×
Command pulse divider/multiplier
switching
DIV1
Ch
8ch
×
Speed 1 of internal velocity
command
INTSPD1
Eh
8Eh
×
Speed 2 of internal velocity
command
INTSPD2
Fh
8Fh
×
Speed 3 of internal velocity
command
INTSPD3
10h
90h
×
Zero speed clamp
ZEROSPD
11h
91h
×
Velocity command sign
VC-SIGN
12h
92h
×
Torque command sign
TC-SIGN
13h
93h
×
Forced alarm
E-STOP
14h
94h
×
Home switch
HOME-SWITCH
16h
96h
Bit2
·
Please don’t set anything other than listed in table above.