User Manual Of EL7-EC** AC Servo
113
Index
6072h
Label
Maximum torque
Unit 0.1%
Structure
VAR
Type
UInt 16
Access
RW
Mapping RPDO Mode F
Range
0~65535 Default 3000
To set max. torque for servo driver. Limited by motor max. torque.
Index
6073h
Label
Maximum current
Unit 0.1%
Structure
VAR
Type
UInt 16
Access
R0
Mapping TPDO Mode F
Range
0~65535 Default 3000
To set max. current for servo driver.
Index
6074h
Label
Internal command
torque
Unit 0.1%
Structure
VAR
Type
Int 16
Access
R0
Mapping TPDO Mode F
Range
-32768~
32767
Default
0
Internal command torque
Index
6075h
Label
Motor current rating
Unit mA
Structure
VAR
Type
Int 32
Access
R0
Mapping TPDO Mode F
Range
0~21474
83647
Default 3000
Shows motor rated current.
Index
6077h
Label
Actual torque
Unit 0.1%
Structure
VAR
Type
Int 16
Access
R0
Mapping TPDO Mode F
Range
-32768~
32767
Default 0
Shows servo driver actual torque feedback
Index
6079h
Label
DC bus voltage
Unit mV
Structure
VAR
Type
UInt
32
Access
R0
Mapping
TPDO Mode F
Range
0~21474
83647
Default 0
Shows DC bus voltage across P, N terminals
Index
607Ah
Label
Target position
Unit
Command
unit
Structure
VAR
Type
Int
32
Access
R
W
Mapping
TPDO Mode PP/CSP
Range
-214748364
7~21474836
47
Default 0
To set the target position under protocol and cyclic position mode.