Pr6.63
Label
Absolute multiturn data
upper limit
Mode
F
Range
0~32766
Unit
rev
Default
0
Index
2663h
Activation
After restart
To set upper limit of multiturn data with absolute encoder set as rotational mode.
When Pr0.15 = 2 and use in combination with Pr6.54:
Feedback load position 6064=
54
.
6
PA
63
.
6
PA
x Electronic gear ratio
3.3 402 Parameters Function
Panel Display as follows:
Parameter Valid mode Description
CSP: Valid in cyclic synchronous position mode
CSV: Valid in cyclic synchronous velocity mode
CST: Valid in cyclic synchronous torque mode
HM: Valid in homing mode
PP: Valid in profile position mode
PV: Valid in profile velocity mode
PT: Valid in profile torque mode
F: Valid in all modes
Index
603Fh
Label
Error code
Unit
-
Structure
VAR
Type
Uint 16
Access
RO
Mapping TPDO
Mode
F
Range
0x0~0
xFFFF Default 0X0
Please refer to Chapter 9 for more details on error codes.
Index
6040h
Label
Control word
Unit
-
Structure
VAR
Type
Uint 16
Access
RW
Mapping RPDO
Mode
F
Range
0x0-0