8-63
Cisco Catalyst Switch Manager User Guide
OL-4930-01
Chapter 8 Interface and Subinterface Management
ATM/SONET Interface Management Window
•
Last Change—The value (in seconds) of sysUpTime at the time the interface entered its current
operational state. If the current state was entered before the last reinitialization of the local network
management subsystem, then this object contains a zero value. This attribute is read-only.
•
Connector Present—Indication if a cable is connected to the interface. If the ifAdminStatus is down,
then this value cannot be determined and an “unknown” message is given. This attribute is read-only.
This attribute can have the following values:
–
yes—Cable is connected to the interface.
–
no—Cable is not connected to the interface.
–
unknown—Cannot determine if a cable is connected to the interface.
•
Number of Resets—Number of times the interface internally reset. This attribute is read-only.
ATM/SONET
The ATM/SONET area provides the following information:
•
SONET Section Status—Status of the SONET Section. This status may indicate multiple
simultaneous defects. This has one of the following values:
–
sonetSectionNoDefect—No defect.
–
sonetSectionLOS—Error condition, Loss Of Signal.
–
sonetSectionLOF—Error condition, Loss Of Frame.
•
SONET Line Status—Status of the SONET Line. This status may indicate multiple simultaneous
defects. This can have one of the following values:
–
sonetLineNoDefect—No defect.
–
sonetLineAIS—Line defect Alarm Indication Signal.
–
sonetLineRDI—Line defect Remote Defect Indication.
•
SONET Path Status—Status of the SONET Path. This status may indicate multiple simultaneous
defects. This can have one of the following values:
–
sonetPathNoDefect—No defect.
–
sonetPathSTSLOP—STS-Path Loss of Pointer.
–
sonetPathSTSAIS—STS-Path Alarm Indication Signal.
–
sonetPathSTSRDI—STS-Path Remote Defect Indication.
–
sonetPathUnequipped—Unequipped.
–
sonetPathSignalLabelMismatch—Signal Label Mismatch.
Performance Logging
The Performance Logging area contains buttons to enable data logging of all the interface attributes of
the interface:
•
Start—Turns on performance data logging.
•
Stop—Turns off performance data logging.
Содержание WS-C3550-12G
Страница 20: ...Contents xx Cisco Catalyst Switch Manager User Guide OL 4930 01 ...
Страница 388: ...11 36 Cisco Catalyst Switch Manager User Guide OL 4930 01 Chapter 11 Routing Management IS IS Management Window ...
Страница 398: ...12 10 Cisco Catalyst Switch Manager User Guide OL 4930 01 Chapter 12 Profile Management Syslog Profile ...
Страница 436: ...A 2 Cisco Catalyst Switch Manager User Guide OL 4930 01 Appendix A Modifying ini Files ...