7-308
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
Code
E061
Cause
• Video controller PCB (faulty)
• Laser unit (faulty)
• Laser intensity (adjustment fault)
• Photosensitive drum (faulty)
• Scanner (faulty)
• Potential measurement unit
(faulty)
• HVDC (faulty)
• Potential measurement unit
(faulty)
• DC controller PCB (faulty)
• Potential measurement unit
(faulty)
• HVDC (faulty)
• Video controller PCB (faulty)
• Laser unit (faulty)
• Laser shutter (faulty)
• Scanner (faulty)
• Environment sensor (faulty)
• Photosensitive drum (faulty)
• Photosensitive drum (poor
grounding)
Description
xx30
The measurement of VD1 is 400 V or
higher.
xx31
The measurement of VD1 is 200 V or
lower.
xx32
The measurement of VD2 is 800 V or
higher.
xx33
The measurement of VD2 is 500 V or
lower.
xx34
The measurement of VL1 is 200 V or
higher.
xx35
The measurement of VL2 is 400 V or
more.
xx36
The measurement of VL2 is 0 V or
lower.
xx50
The difference between the computation
value of VD measured previously and
the computation value of VL measured
currently is 30 V or more.
xx51
The difference between the computa-
tion value of Vg measured previously
and the computation value of Vg
measured currently is 30 V or more.
xx52
The computation value of V00 is the
upper limit value (950 v) or higher.
xx53
The computation value of V00 is the
lower limit value (325 V) or lower.
Содержание Vizcam 1000
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...