7-99
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
Cause
Toner density
sensor
DC controller
PCB
SALT sensor
Photosensitive
drum
Step
5
6
7
8
Checks
Is ‘E020’ for the SALT sensor?
Detailed code XXXX
↑−
Numeral: SALT
sensor
Alphabet: toner
density sensor
Replace the toner density sensor of
the color for which ‘E020’ is indi-
cated. Is the problem corrected?
Is the front cover open while the
transfer frame front cover is removed
(i.e., is the SALT sensor subject to
stray light)?
Replace the photosensitive drum. Is
the problem corrected?
Yes/No
YES
YES
NO
YES
NO
YES
NO
Action
Go to step 7.
End.
• Be sure to replace the
developer after replac-
ing the toner density
sensor.
Replace the DC controller
PCB.
Install the transfer frame
front cover.
Replace the SALT sensor.
• Be sure to replace the
developer after replac-
ing the toner density
sensor.
End.
Replace the DC controller
PCB.
Содержание Vizcam 1000
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...