COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-59
4. MECHANICAL SYSTEM
B. Pre-Exposure System
1. Removing the Pre-Exposure
System
1)
Open the front cover, and slide out the
process unit.
2)
Keep the transfer unit out.
3)
Remove the developing assembly/cleaning
unit and the photosensitive drum that
corresponds to the pre-exposure lamp to be
removed.
4)
Cover the other developing assemblies/
cleaning units and photosensitive drums with
paper.
5)
Remove the screw [1], and disconnect the two
connectors [3]; then, pull out the primary
charging assembly rail 3 to the front.
At this time, take care not to drop the primary
charging assembly rail.
Figure 4-501B
6)
Remove the screw, and slide out the pre-
exposure lamp PCB.
[2]
[2]
[1]
[3]
Tighten the screw while butting the
rail against the front side plate.
Figure 4-502B
Butted.