7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
25
Correcting Skew Movement
(slope of the registration roller
unit)
If you must correct skew movement after re-
placing the registration roller unit, perform the fol-
lowing:
1) Remove the transfer right cover and the front
right cover.
2) Loosen the two mounting screws [1] on the
registration roller unit.
[1]
Figure 7-268
3) Adjust the screw [2] used to position the fixing
plate.
• The leading edge of paper will be toward the
front in relation to the movement of feeding
(CW).
[2]
Figure 7-269
ccw cw
Screw 2
Registration
roller unit
Transfer belt
Paper
Conceptual diagram
cw
ccw
Figure 7-270
4) After making adjustments, fully tighten the
screw loosened in step 2).