COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-45
4. MECHANICAL SYSTEM
3. Removing the Transfer Belt
a.
Without Removing the Transfer Unit from
the Copier
1)
Slide out the transfer unit assembly to the
front, and remove the transfer front cover.
2)
Shift up the separation paper guide [1], and
move it to the rear to remove.
4)
Open the transfer belt assembly. (See the
instructions on how to open the transfer belt
assembly.)
5)
Loosen the mounting screw [5], and free the
sensor unit fixing plate [4].
Figure 4-413A
3)
Remove the three screws [2], and remove the
grounding roller unit [3].
Figure 4-414Aa
[1]
[2]
[3]
Figure 4-414Ab
6)
Push down the sensor unit [6], and butt the
sensor unit fixing plate [4] in the direction of
the arrow; then, tighten the screw [5], and fix
the sensor unit [6] and the sensor unit fixing
plate [4] in place.
Figure 4-414Ac
[4]
[5]
[6]
[5]
[4]