7-118
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
b. E194=0001, 0002
n
Correcting E194=0001/0002
1) Turn off the power switch.
2) Open the front cover.
3) Remove the image position correction CCD unit. (See the descriptions under “Removing the Image
Position Correction CCD Unit” in Chapter 4.)
4) Remove the drive releasing pin [1], and dry moving the shutter [3] while holding the mobile member.
[3]
[2]
[1]
Figure 7-404
Cause
Shutter drive
motor (M25)
Shutter open
sensor (PS40)
Shutter closed
sensor (PS39)
Shutter drive
system
Parts (deforma-
tion, dirt)
Step
1
2
3
4
5
Checks
Execute ‘UFNC > F-MISCp > MTR’
in service mode to operate the
shutter. Does the shutter drive motor
operate normally?
Is the shutter open sensor (PS40)
normal? (in the case of E194-0001)
Is the shutter closed sensor (PS39)
normal (if E194=0002)?
Check the shutter drive system as
shown below. Does it move
smoothly?
Is the shutter screw assembly
soiled?
Yes/No
YES
NO
NO
YES
NO
YES
Action
Check the drive system; if
normal, replace the motor.
Replace the sensor.
Replace the sensor.
Check the wiring; if
normal, replace the DC
controller PCB.
Check the wiring; if
normal, replace the CCD
unit used for image
position correction.
Disassembly/clean the
parts as shown next page.
Содержание Vizcam 1000
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...