7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
13
Adjusting the Pressure of the
Multifeeder Separation Roller
If double-feeding or pick-up faults occur during
pick-up operation, change the position of the pres-
sure spring [2] of the separation roller [1].
a. If double-feeding occurs, move the spring
holder in the direction of A. (decrease the pres-
sure)
b. If pick-up faults occur, move the position of the
spring holder in the direction of B. (increace the
pressure)
A
B
[2]
[1]
Figure 7-256
14
Adjusting the Position of the
Multifeeder Pick-Up Roller
Releasing Solenoid (SL5)
Install the solenoid so that the distance be-
tween the solenoid arm [2] and the rear side plate
[3] is 3.5 ±0.2 mm when the plunger of the solenoid
[1] is pushed in.
3.5±0.2mm
[1]
[3]
[2]
Figure 7-257 (rear)
15
Adjusting the Position of the
Duplexing Unit Pick-Up Roller
Releasing Solenoid (SL8)
1) Remove the pick-up assembly.
2) Lift the lever [1] as shown, and let the pick-up
roller [2] drop on its own weight.
3) Adjust the position of the solenoid so that the
distance L is 43 ±1 mm when the plunger is
pushed in.
Make adjustments while the pin [4] is
in contact with the bottom end of the
long hole.
L
[1]
[2]
[3]
[4]
Figure 7-258
Содержание Vizcam 1000
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...