![Canon Vizcam 1000 Скачать руководство пользователя страница 476](http://html1.mh-extra.com/html/canon/vizcam-1000/vizcam-1000_service-manual_3951549476.webp)
7-40
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
6
Laser Focus Adjustment
1) Check to make sure that the marking [1] on the
lens assembly matches the marking [2] on the
lens mount (standard position).
[1]
[2]
Figure 7-276
If the unit is not in standard position, loosen the
locking nut [3], and turn the lens assembly until the
distance to the end [4] of the lens assembly is 27.3
±0.2 mm, i.e., where the markings match.
27.3±0.2mm
[4]
[3]
Figure 7-277
2) Perform focusing adjustments by turning the
lens assembly once again according to the val-
ues recorded on the label. For instance, if the
value is “+2/8,” turn the lens assembly in the
positive direction (counterclockwise when
viewing from the end of the lens assembly)
over two notches.
8
R
FS6-8028
Feed length label
Figure 7-278
Positive direction
Figure 7-279
3) Tighten the locking nut, and fix the position of
the lens in place.