Code
E023
E030
E032
Cause
• Developing motor (faulty)
• DC controller PCB (faulty)
• Developing cylinder (rotation
failure)
• Counter (open circuit)
• DC controller PCB (faulty)
Data communication (error between
Copy Data Controller-A1 and
copier)
Description
0101
The rotation speed of the Y developing
motor (M18Y) has deviated from a
specific value for 0.1 sec or more (PLL
signal ‘0’).
0201
The rotation speed of the M developing
assembly (M18M) has deviated from a
specific value for 0.1 sec or more (PLL
signal ‘0’).
0301
The rotation speed of the C developing
motor (M18C) has deviated from a
specific value for 0.1 sec or more (PLL
signal ‘0’).
0401
The rotation speed of the Bk develop-
ing motor (M18Bk) has deviated from a
specific speed for 0.1 sec or more (PLL
signal ‘0’).
Check immediately before the counter turns
ON and OFF.
(Normal if the counter drive signal is ‘0’ when
the counter turns ON; normal if the counter
drive signal is ‘1’ when the counter turns OFF.)
After the copier has generated the copy start
signal, count pulses have not been detected by
the data Controller-A1 within a specific period
of time.
Содержание Vizcam 1000
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...