4. MECHANICAL SYSTEM
Figure 4-705A
5)
Release the lock [7] found in the lower left of
the hopper.
6)
Return the hopper assembly [8] where the
middle position metal fixing [8] installed in step
4) is located.
8)
Secure the hopper assembly [8] to the midway
metal fixing (left, right) with screw each [10].
Figure 4-706A
7)
Remove the screw [9] from the left grip
assembly.
Figure 4-708A
9)
Lift the right end of the control panel, and push
in the slider [11] to remove the control panel.
Figure 4-707A
Figure 4-709A
10) Lift the hopper assembly by holding it on its
top left and right to remove.
[6]
[7]
[6]
[8]
[9]
[11]
[10]
[8]