Appendix A Specifications
A-32
Table A.3.11-2 CRU Output
Item
Specifications
Output Mode
The signal output from CRU Output can be selected from Recovered Clock or
input signal.
The through output of the input signal can be output only when the input
signal is Clock.
Recovered Mode
When CRU Output is set to Recovery Clock
Amplitude
Typical
480 mVp-p
Clock Frequency
12.75 to 14.1 GHz (Half Rate Clock)
Additive Jitter
(RMS)
Typical
250 fs*
1,
*
2,
*
3
Max.
400 fs*
1,
*
4
Loop Bandwidth
Selectable from the list as follows.
4MHz
10MHz
Bitrate/1667
Attenuation: –20 dB/dec
Lock Detection
Detection function is available.
Through Mode
When CRU Output is set to Through
Amplitude
Typical
500 mVp-p
Operation
Frequency
0.1 to 1.7625 GHz (1.7625 GHz is the 1/16 Clock of 28.2 GHz)
Additive Jitter
(RMS)
Typical
200 fs*
3,
*
4,
*
5
Max.
400 fs*
4,
*
5
Connector
SMA, female
Termination
50
Ω
, AC coupled
Waveform Format
Square wave
*1: With 25.78125 Gbit/s, 26.5625 Gbit/s, and 28.05 Gbit/s, 1/4Clock
Pattern, Loop Bandwidth = 10 MHz, Single-ended, using MP2110A
PPG
*2: Input amplitude 400±100 mVp-p
*3: At 25±5°C
*4: Input amplitude 400 mVp-p
*5: With 25.78125 Gbit/s, 26.5625 Gbit/s, and 28.05 Gbit/s, 1/16Clock
Pattern, Single-ended, using MP2110A PPG
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...