Appendix A Specifications
A-26
A.3.10 Optical Channel
Table A.3.10-1 Optical Channel Function
Item
Specifications
Amplitude Setting
Scale
Scale setting on the vertical axis.
1 to 200 µW /div, 1 µW step
Offset
Offset setting on the vertical axis. Both ChA and ChB can be set as follows.
–500 to 500µW, 1 µW step
Attenuation
Function of correcting Amplitude Scale / Offset and measurement result in
conjunction with the input attenuation of the attenuator connected to Data
Input
0.00 to 30.00 dB, 0.01 dB step
Tracking*
Function to make the other channel track the active channel’s Scale, Offset
and Attenuation values.
ON/OFF
Channel Math
Function not available
Filter Selection
Sets the bandwidth of O/E Input Port to No Filter or Reference Receiver
compliant filters.
Refer to Filter Response in Table A.3.10-2 for supported filters.
Extinction Ratio
Correction
Extinction ratio correction function
Correction Enable
ON/OFF
Correction Factor
–9.99 to +9.99 %, 0.01% step
Conversion Gain
Adjusts two conversion gains. One is for SMF Input and the other is for
MMF Input.
Responsivity
Adjusts two responsivities. One is for SMF Input and the other is for MMF
Input.
Calibration
Conversion Gain / Responsivity Calibration, O/E Calibration
*: Available when MP2110A-x22, MP2110A-x30, MP2110A-x32,
MP2110A-x39, MP2110A-x40, MP2110A-x42 or MP2110A-x49 is
installed
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...