
Chapter 5 How to Operate BERT
5-16
5.2.6
Setting Clk Out
Set a signal output from the
Clk Out
connector on the front panel.
Clk Out is a function to output the clock synchronized to the data
generated from the pulse pattern generator to the
Clk Out
connector on
the front panel. The
Clk Out
connector is AC-coupled.
To measure the eye waveform using the sampling oscilloscope, connect the
Clk Out
connector and the
Trigger Clk In
connector of the sampling
oscilloscope using a coaxial cable.
For MP2110A-093, the clock output division rate is automatically changed
according to the bit rate.
24.3 to 28.2 Gbit/s:
1/4Clock
9.5 to 14.2 Gbit/s:
1/2Clock
For MP2110A-014, the clock source of clock output is selected from Ch1/2
or Ch3/4.
The jitter is reduced by matching the channel used for the measurement
and the channel at Clk Out as shown in Figure 5.2.6-1. Refer to the
descriptions at Jitter in Section A.2.2, “Pulse Pattern Generator”, for
details of the jitter.
To perform the measurement using PPG/ED Ch1 and PPG/ED Ch2, set
Ch1/2.
Figure 5.2.6-1 Connection Example When Setting Ch1/2 at Clk Out
To perform the measurement using PPG/ED Ch3 and PPG/ED Ch4, set
Ch3/4.
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...