9. Connect the 20 dB fixed attenuator and
ED1 Data In
connector
using a coaxial cable. (Refer to (b) in Figure 7.2.2-1.)
10. Click Start at All Measurements.
11. Record the error rate ER for the ED Result after measurement is
complete.
12. Connect the 20 dB fixed attenuator and
Ch A In
connector using
a coaxial cable.
13. Click PPG/ED Ch1. Change Bit Rate to following value.
28200000 kbit/s, 100 ppm
14. Repeat steps 7 and 11.
15. Connect coaxial terminators to the
PPG1 Data Out
and
ED1
Data In
connectors. (Refer to (a) in Figure 7.2.2-2.)
16. Attach the 20 dB fixed attenuator to the
PPG1
Data
Out
connector.
17. Connect the 20 dB fixed attenuator
and
Ch A In
connector using
a coaxial cable.
18. Repeat steps 7 and 8.
19. Connect the 20 dB fixed attenuator and
ED1
Data
In
connector
using a coaxial cable. (Refer to (b) in Figure 7.2.2-2.)
20. Click PPG/ED Ch1.
21. Set Data Input Condition to Single-Ended XData.
22. Repeat steps 10 to 11.
23. Click PPG/ED Ch1. Change Bit Rate to following value.
When MP2110A-093 is not installed: 24300000 kbit/s, –100 ppm
When MP2110A-093 is installed: 9500000 kbit/s, –100 ppm
24. Connect the 20 dB fixed attenuator and
Ch A In
connector using
a coaxial cable.
25. Repeat steps 7 and 8.
26. Connect the 20 dB fixed attenuator and
ED1
Data
In
connector
using a coaxial cable. (Refer to (b) in Figure 7.2.2-2.)
27. Repeat steps 10 and 11.
For ED2 to ED4, perform tests in the same way. For ED3 and ED4 test,
change the Clock Output in step 4 to the following value.
Item
Setting Value
Clock Output
Ch3/4
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...