Chapter 6 How to Operate Sampling Scope
6-28
Table 6.2.3-2 Items of Setup Dialog Box (Utilities tab)
Item
Description
Waveform
Selects the color of waveform from Color Grade or Gray
Scale. It does not apply to jitter graphs.
When Gray Scale is selected, click Color Select, and you
can set the waveform color.
Mask*
1
Selects the color of mask from Purple or Gray.
Preset Information*
1
On: Displays the setting information (vertical
axis/horizontal axis scale, offset, symbol rate, status
of precision trigger (On/Off)) in the waveform
display area.
Off: Hides the setting information other than GND.
Label Add*
1
Adds a new label.
Label Delete*
1
Deletes the displayed label.
Overload
On:
Displays a warning (Overload/Clipped) as shown in
Figure 6.2.1-5 when the input signal level becomes
excessively high. If a warning is displayed, N/A is
displayed as a measurement result.
Off:
Does not display a warning (Overload/Clipped).
Questionable Eye
On:
Displays N/A as a measurement result except for
Average Power when NRZ? or PAM4? is displayed in
the measurement result/marker display area. NRZ?
and PAM4? indicate that the input signal may not be
measured correctly (refer to Figure 6.9.1-3).
However, in Version 7.02.10 or later, they are all
displayed as N/A except for Average Power, Outer
OMA, and Outer ExR.
Off:
Displays measurement results even when NRZ? or
PAM4? is displayed.
Set Reference*
1
Saves the displayed waveform as the reference trace.
Clear Reference*
1
Deletes the reference trace.
Temperature
Displays the temperature of the sampling oscilloscope.
Current: Displays the current temperature.
Last Calibration:
Displays the temperature at the last
calibration, together with date and time.
Calibration*
2
Calibrates the amplitude level of the sampling
oscilloscope.
Application Test*
2
Runs the self test for the sampling oscilloscope.
*1: If Sampling Mode is set to Advanced Jitter, the setting is not
reflected.
*2: Operation is not possible when Sampling Mode is set to Advanced
Jitter.
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...