A.3 Sampling Oscilloscope
A-29
A
ppe
ndi
x A
Table A.3.10-2 Optical Channel Performance (Cont’d)
Item
Specifications
Mask Sensitivity
When MP2110A-022, 023, 025, 026, 032, 033, 035, 036, or 039 is installed:
When MP2110A-054 is not
installed
When MP2110A-054 is installed*
2
SMF: Typ. –15.0 dBm
(1310 nm, OTU4 Filter)
MMF: Typ. –12.0 dBm
(850 nm, OTU4 Filter)
SMF: Typ. –13.5 dBm
(1310 nm, OTU4 Filter)
MMF: Typ. –10.5 dBm
(850 nm, OTU4 Filter)
When MP2110A-030 is installed:
When MP2110A-054 is not
installed
When MP2110A-054 is installed*
2
SMF: Typ. –13.5 dBm
(1310 nm, OTU4 Filter)
SMF: Typ. –12.0 dBm
(1310 nm, OTU4 Filter)
When MP2110A-040 is installed:
When MP2110A-054 is not
installed
When MP2110A-054 is installed*
2
SMF: Typ. –12.0 dBm
(1310 nm, OTU4 Filter)
SMF: Typ. –10.5 dBm
(1310 nm, OTU4 Filter)
When MP2110A-042, 043, 045, 046, or 049 is installed:
When MP2110A-054 is not
installed
When MP2110A-054 is installed*
2
SMF: Typ. –14.0 dBm
(1310 nm, OTU4 Filter)
MMF: Typ. –12.0 dBm
(850 nm, OTU4 Filter)
SMF: Typ. –12.5 dBm
(1310 nm, OTU4 Filter)
MMF: Typ. –10.5 dBm
(850 nm, OTU4 Filter)
Estimated optical power at which Mask Margin reaches 0%
(calculated from the optical noise level)
Maximum Input
Power (Before
Distortion)
When MP2110A-022, 023, 025, 026, 032, 033, 035, 036, 039, 042, 043, 045,
046, or 049 is installed:
Typical –2 dBm (SMF Input), @ the signal of 1310 nm, ExR = 8 dB is
observed.
T2 dBm (MMF Input), @ the signal of 850 nm, ExR = 3 dB is
observed.
When MP2110A-030 or 040 is installed:
T2 dBm (SMF Input), @ the signal of 1310 nm, ExR = 4 dB is
observed.
Absolute Maximum
Power (Before
Damage)
<Average>
+5 dBm (SMF Input), +7 dBm (MMF Input)
<Peak>
+8 dBm (SMF Input), +10 dBm (MMF Input)
Optical Return Loss Typical –27 dB (SMF Input), @ 1310 nm SMF Fiber is connected
Typical –20 dB (MMF Input), @ 850 nm MMF Fiber is connected
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...