Chapter 6 How to Operate Sampling Scope
6-40
Table 6.2.4-5 Settable Standards for PDJ measurement and Filter Sets (Unit Hz)
PDJ Filter
Standard
HP0
HP1
HP1'
HP2
HP'
HP
LP
LP'
STM-0
10
100
–
20 k
–
12 k
400 k
–
STM-1
10
500
–
65 k
–
12 k
1.3 M
500
STM-4
10
1 k
–
250 k
–
12 k
5 M
1 k
STM-16
10
5 k
–
1 M
–
12 k
20 M
5 k
STM-64
10
20 k
10 k
4 M
50 k
12 k
80 M
20 k
STM-256
–
80 k
20 k
16 M
–
–
320 M
–
The jitter specification values specified in ITU-T G.825/Amd.1 Table 1 are
shown in the following table.
Table 6.2.4-6 Maximum permissible jitter at network interfaces
Interface
Measurement bandwidth,
–3dB frequencies (Hz)
Peak-to peak
amplitude (UIpp)
STM-1e
500 to 1.3 M
1.5
(Notes 1, 2)
65 k to 1.3 M
0.075
STM-1
500 to 1.3 M
1.5
(Note 3)
65 k to 1.3 M
0.15
STM-4
1 k to 5 M
1.5
(Note 3)
250 k to 5 M
0.15
STM-16
5 k to 20 M
1.5
(Note 3)
1 M to 20 M
0.15
STM-64
20 k to 80 M
1.5
(Note 3)
4 M to 80 M
0.15
STM-256
80 k to 320 M
1.5
(Note 3)
16 M to 320 M
0.18
NOTE 1
−
Electrical format CMI-encoded, according to G.703.
NOTE 2
−
For networks deployed with G.813 Option II clocks or G.812
Type II, III or IV clocks, STM-1 requirements apply to STM-1e.
NOTE 3
−
STM-1 1 UI = 6.43 ns
STM-4 1 UI = 1.61 ns
STM-16 1 UI = 0.402 ns
STM-64 1 UI = 0.100 ns
STM-256
1 UI = 0.025 ns
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...