6.9 Measuring
Waveform
6-97
6
How to Operate Sampling Scope
To select channel and mask
1. Click
Measure to open the Measure dialog box.
2. Click
Mask Test tab.
3. Click Target Channel button, and then select the channel to be
measured. The next channel cannot be selected.
Channel whose signal type is set to PAM4.
Channel whose Sampling Mode is set to Advanced Jitter.
4. Click the Eye Mask Select button to select the mask.
5. The file selection dialog box is opened. Click the mask file and OK.
The selected mask or mask file is displayed in the Current Mask box of
the measurement results. Refer to Figure 6.9.2-2 “Mask Test Example”.
Table 6.9.2-1 Mask List
Mask Name
Standard
Bit Rate
100GbE-ER4_Tx.txt 100GbE-ER4 25.78125
Gbit/s
100GbE-LR4_Tx.txt 100GbE-LR4
25.78125
Gbit/s
100GbE-SR4_Rx.txt 100GbE-SR4
25.78125
Gbit/s
100GbE-SR4_Tx.txt 100GbE-SR4
25.78125
Gbit/s
100GbE-CLR4-FEC.txt
100GbE-CLR4 FEC 25.78125 Gbit/s
100GbE-CLR4.txt 100GbE-CLR4
25.78125
Gbit/s
100GbE-CWDM4.txt 100GbE-CWDM4
25.78125
Gbit/s
OTU-4.txt OTU-4
27.952493
Gbit/s
32GFC_MM.txt 32GFC
28.05
Gbit/s
32GFC_SM.txt 32GFC
28.05
Gbit/s
8GFC_Elect_Rx.txt 8GFC
8.5
Gbit/s
8GFC_Elect_Tx.txt 8GFC
8.5
Gbit/s
InfiniBand_EDR_Cable_In_Limiting.txt
InfiniBand EDR
25.78125 Gbit/s
InfiniBand_EDR_Cable_Out_Limiting.txt
InfiniBand EDR
25.78125 Gbit/s
InfiniBand_EDR_Host_Out_Limiting.txt
InfiniBand EDR
25.78125 Gbit/s
InfiniBand_EDR_Stressed_In_Limiting.txt
InfiniBand EDR
25.78125 Gbit/s
HDMI_TP1.txt*
1
HDMI
*
3
HDMI_TP2.txt*
2
HDMI
*
3
*1: Mask file for HDMI transmitter
*2: Mask file for HDMI receiver
*3: Bit rate is unspecified.
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...
Страница 466: ...Index Index 6...