6 - 28
–
+
ELEC
SIGNALING SYSTEM
3. Measure:
• Multi-function display output voltage
Out of specification
→
Replace multi-
function display.
CAUTION:
Make sure that a short-circuit does not
develop between the terminals because it
may cause damage to electrical compo-
nents.
Tester (+) lead
→
Red lead
1
Tester (–) lead
→
Black/White lead
2
Multi-function dis-
play output voltage
Tester selec-
tor position
4.5 V or more
DCV-20
SPEED SENSOR OUTPUT VOLTAGE
INSPECTION
1. Insert the thin electric conductors
1
(lead)
into the speed sensor coupler
2
, as
shown, and connect the tester to them.
CAUTION:
• Do not insert the electric conductors
more than required because it may
reduce the waterproof function of the
coupler.
• Make sure that a short-circuit does not
develop between the terminals because it
may cause damage to electrical compo-
nents.
2. Set the main switch to “ON”.
Tester (+) lead
→
White lead
3
Tester (–) lead
→
Black lead
4