BUS Updated 12/2011
07/2011
2-911
WorkCentre 5335 Family Service Documentation
116-790
Status Indicator RAPs
Initial Issue
116-790 Stapling Canceled RAP (Finisher LX)
BSD-ON:
BSD 12.21 - Office Finisher LX Staple Control
When Staple was specified, there were no staples.
1.
If the operator stops a FAX/Internet FAX Mailbox received documents print, cancel one of
the lead Stapler and print.
2.
If 1. is not possible, cancel Stapler for all copy and print
Initial Actions
Power Off/On
Procedure
Execute
Component Control
[012-242 Low Staple Sensor]. Install and remove the Staple Car-
tridge. The display changes.
Y
N
Check the Staple Cartridge for failure or foreign substances. There are no foreign sub-
stances and nothing has failed.
Y
N
Repair the failure and remove the foreign substances.
Check the wires between
J8886
and
P/J8981
for a loose connection, or an open or a
short circuit. The wires are OK.
Y
N
Repair as required.
Measure the voltage between the Finisher PWB
J8886
-5 (+) and GND (-). The voltage
is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 22.7
).
Measure the voltage between the Finisher PWB
J8886
-7 (+) and GND (-). Install and
remove the Staple Cartridge. The voltage changes.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Replace the Staple Assembly (
PL 23.4
) If the problem persists, replace the Finisher PWB
(
PL 23.16
).
Check the sw version of the controller sw - update if required. Replace the Finisher PWB (
PL
23.16
).