BUS Updated 12/2011
07/2011
2-124
WorkCentre 5335 Family Service Documentation
012-295, 012-296
Initial Issue
Status Indicator RAPs
012-295 Stapler Move Position Sensor On Failure RAP (LX)
BSD-ON:
BSD 12.20 - Office Finisher LX Staple Positioning
•
After the Stapler started moving to the staple position, the Stapler Move Position Sensor
did not turn On within 2sec.
•
After the Stapler completed moving to the Staple Position, the Stapler Move Position Sen-
sor did not turn On.
Initial Actions
Check the Stapler, Base Frame, and Rail (
PL 23.8
) for freedom of movement.
Procedure
Execute
Component Control
[012-241], Stapler Move Position Sensor. Move the Stapler by
hand from the Home position to the staple position and back. The display changes.
Y
N
Check the wire between
J8885
pin 2 on the Stapler Move Position Sensor and
P/J8981
pin 2 on the Finisher PWB for an open or short circuit, or loose or damaged connectors.
The wire is OK.
Y
N
Repair/replace as required.
Measure the voltage between
P/J8981
, pins 3 and 1 on the Finisher PWB
BSD 12.20 -
Office Finisher LX Staple Positioning
. The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Measure the voltage between
P/J8981
pin 2 on the Finisher PWB and GND
BSD 12.20 -
Office Finisher LX Staple Positioning
Move the Stapler by hand from the Home position
to the staple position and back. The voltage changes.
Y
N
Replace the Stapler Move Position Sensor (
PL 23.8
).
Replace the Finisher PWB (
PL 23.16
).
Alternately execute
Component Control
[012-045], Staple Move Motor Rear and [012-042],
Staple Move Motor Front. The Stapler Move Motor moves.
Y
N
Check the wires between
P/J8981
pins 13~16 on the Finisher PWB and
P/J8888
on the
Stapler Move Motor
BSD 12.20 - Office Finisher LX Staple Positioning
for an open or
short circuit, or loose or damaged connectors. The wires are OK.
Y
N
Repair/replace as required.
Replace the Staple Move Motor (
PL 23.8
). If the problem persists, replace the Finisher
PWB (
PL 23.16
).
Go to
BSD 12.20 - Office Finisher LX Staple Positioning
Check for an intermittent connec-
tion. If the check is good, replace the Stapler Assembly (
PL 23.8
). If the problem continues,
replace the Finisher PWB (
PL 23.16
).
012-296 Staple Move Sensor Off Failure RAP (LX)
BSD-ON:
BSD 12.20 - Office Finisher LX Staple Positioning
•
After the Stapler started moving to the Staple Position and the Staple Move Sensor turned
Off, the Staple Move Sensor did not turn Off within 500ms.
•
After the Staple Position had been fixed, the Staple Move Sensor turned Off.
•
After the Staple Move Sensor turned On when paper passed through the Dual Staple 1
Position while moving to the Rear Staple Position, the Staple Move Sensor did not turn Off
within 500ms.
Initial Actions
Check the Stapler, Base Frame, and Rail (
PL 23.8
) for freedom of movement.
Procedure
Execute
Component Control
[012-241], Stapler Move Position Sensor. Move the Stapler by
hand from the Home position to the staple position and back. The display changes.
Y
N
Check the wire between
J8885
pin 2 on the Stapler Move Position Sensor and
P/J8981
pin 2 on the Finisher PWB for an open or short circuit, or loose or damaged connectors.
The wire is OK.
Y
N
Repair/replace as required.
Measure the voltage between
P/J8981
, pins 3 and 1 on the Finisher PWB
BSD 12.20 -
Office Finisher LX Staple Positioning
. The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Measure the voltage between
P/J8981
pin 2 on the Finisher PWB and GND
BSD 12.20 -
Office Finisher LX Staple Positioning
). Move the Stapler by hand from the Home posi-
tion to the staple position and back. The voltage changes.
Y
N
Replace the Stapler Move Position Sensor (
PL 23.8
).
Replace the Finisher PWB (
PL 23.16
).
Alternately execute
Component Control
[012-045], Staple Move Motor Rear and [012-042],
Staple Move Motor Front. The Stapler Move Motor moves.
Y
N
Check the wires between
P/J8981
pins 13~16 on the Finisher PWB and
P/J8888
on the
Stapler Move Motor
BSD 12.20 - Office Finisher LX Staple Positioning
for an open or
short circuit, or loose or damaged connectors. The wires are OK.
Y
N
Repair/replace as required.
Replace the Staple Move Motor (
PL 23.8
). If the problem persists, replace the Finisher
PWB (
PL 23.16
).
A