BUS Updated 12/2011
07/2011
2-242
WorkCentre 5335 Family Service Documentation
016-726, 016-727
Initial Issue
Status Indicator RAPs
016-726 PDL Auto Switch RAP
Print language auto judgement has failed.
Initial Actions
Power Off/On
Procedure
In parallel connection, check it according to the procedures given below.
1.
Set a longer time for [Auto Output Time] by selecting [Port Settings]>[Parallel] in
CWIS.
2.
Replace the parallel cable.
3.
If a long parallel cable is used, use a short cable (genuine) and try printing again.
4.
Change the print language from [Auto] to [ARTEX] or [PS] fixed by selecting [Emula-
tion Settings]>[Print Mode] in CWIS.
5.
If not in parallel connection, check Step 4 above.
6.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firm-
ware module, EEPROM)
7.
Check the sw version of the controller sw - update if required
016-727 Printer Request RAP
The result of a print request is a zero-page document that cannot be stored in a mailbox, and
the job is canceled. The P-Formatter attempted to store a 0 page document into the Mailbox,
but the job is canceled because 0 page documents cannot be stored
Initial Actions
Power Off/On
Procedure
•
Do not allow the Print Result that is to be stored in the Mailbox to be 0 page.
•
If Paper Saving is "ON", turn it "OFF" and print again. Check that the printed document is
not a blank paper, and input some text if it is blank.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required