BUS Updated 12/2011
07/2011
2-809
WorkCentre 5335 Family Service Documentation
077-301, 077-305
Status Indicator RAPs
Initial Issue
077-301 L/H Cover Interlock Open RAP
BSD-ON:
BSD 1.8 - Power Interlock Switching (1 of 2)
The L/H Cover is open.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The L/H Cover Unit for damage or mismatch
•
The L/H Cover Interlock Switch for failure:
Component Control
[077-300] (
PL 18.2
)
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).
077-305 Tray Module L/H Cover Open RAP
BSD-ON:
BSD 1.8 - Power Interlock Switching (1 of 2)
The Tray Module L/H Cover is open.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Check the following:
•
The Tray Module L/H Cover for damage or mismatch
•
The Tray Module L/H Cover Switch for failure:
Component Control
[077-306] (
PL
11.13
)
•
The connection between the Tray Module L/H Cover Switch
P/J104
and the Tray
Module PWB
P/J548
for open circuit, short circuit, and poor contact
If no problems are found, replace the following parts in sequence:
–
Reload the machine software (
GP 16
).
–
Tray Module PWB (
PL 11.13
)
–
MCU PWB (
PL 18.2
)