BUS Updated 12/2011
07/2011
2-64
WorkCentre 5335 Family Service Documentation
005-122
Initial Issue
Status Indicator RAPs
005-122 DADF Simplex/Side 1 Pre Registration Sensor On
Jam RAP
BSD-ON:
BSD 5.5 - Document Feed (2 of 2)
•
After Pre-Feed started for the first sheet (DADF Feed Motor On (CW)) in Simplex and
Duplex, the DADF Pre Registration Sensor did not turn ON within the specified time.
•
After Pre-Feed started for the second sheet onwards (DADF Feed Motor On (CW)) in
Duplex, the DADF Pre Registration Sensor did not turn ON within the specified time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Open the Top Cover and remove the Invert Chute. Enter the Diag Mode, turn ON
Component
Control
[005-206]. Block the DADF Pre Registration Sensor using a sheet of paper, etc. Does
the display change to High?
Y
N
Disconnect the DADF Pre Registration Sensor connector
P/J774
. Does the display
change to High?
Y
N
Check the wire between the DADF Pre Registration Sensor
P/J774
-2 and the DADF
PWB
P/J757
-11 for a short circuit. If no problems are found, replace the DADF PWB
(
PL 51.2
).
Is the voltage between
P/J774
-1 (+) and
P/J774
-3 (-) +5VDC?
Y
N
Check the wires between the DADF PWB
P/J757
-12 and the DADF Pre Registra-
tion Sensor
P/J774
-1, as well as between the DADF PWB
P/J757
-10 and the
DADF Pre Registration Sensor
P/J774
-3 for open circuits and poor contacts.
Replace the DADF Pre Registration Sensor (
PL 51.17
).
Press the Stop button. Turn ON
Component Control
[005-010] (DADF Feed Motor). Does the
DADF Feed Motor operate?
Y
N
Is the voltage between the DADF Feed Motor
P/J776
-5/2 (+) and the GND (-)
+24VDC?
Y
N
Is the voltage between the DADF PWB
P/J754
-B1/B2 (+) and the GND (-)
+24VDC?
Y
N
Is the voltage between the DADF PWB
P/J753
-2 (+) and the GND (-)
+24VDC?
Y
N
Refer to
BSD 5.1 - Document Setting
and check the +24VDC circuit to the
DADF PWB
P/J753
-2.
Replace the DADF PWB (
PL 51.2
).
Check the wires between the DADF PWB
P/J754
-B1 and the DADF Feed Motor
P/
J776
-5, as well as between the DADF PWB
P/J754
-B2 and the DADF Feed Motor
P/J776
-2 for an open circuit and poor contact.
Turn OFF the power and disconnect
P/J754
from the DADF PWB.
Measure the wire wound resistance of the Motor.
•
Between
P/J754
pin-B1 and
P/J754
pin-B5/B6
•
Between
P/J754
pin-B2 and
P/J754
pin-B3/B4
Is the resistance approximately. 1Ohm for each?
Y
N
Replace the DADF Feed Motor (
PL 51.5
).
Replace the DADF PWB (
PL 51.2
).
Check the following:
•
The document path for foreign substances.
•
Overly strong Retard pressure.
•
The DADF Pre Registration Sensor Actuator for disengagement, drag and damage.
A
A
B
B
C