BUS Updated 12/2011
07/2011
2-514
WorkCentre 5335 Family Service Documentation
033-324, 033-325
Initial Issue
Status Indicator RAPs
033-324 USB State Change Error RAP
BSD-ON:
BSD 34.1 - FAX
USB entered into an unexpected state.
Procedure
•
Switch the power off, then on.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWB’s in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the Fax PWB (
PL 18.5
)
033-325 Fax PWB Fatal Error RAP
BSD-ON:
BSD 34.1 - FAX
Bit error found during debugging of Fax PWB
Procedure
•
Switch the power off, then on.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWB’s in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the Fax PWB (
PL 18.5
)