BUS Updated 12/2011
07/2011
2-405
WorkCentre 5335 Family Service Documentation
024-748, 024-775
Status Indicator RAPs
Initial Issue
024-748 Bates Numbering Digit Over RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Job Fail. The number of Bates Numbering digits is exceeded. In the process of printing Bates
Numbering, a maximum number of 9 or the user-specified number of digits is exceeded.
Procedure
•
Reduce the number of documents to less than the user-specified number or reduce the
number of numbering digits in order to copy them again.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
024-775 Print Booklet Sheets Counts Over (Not Field
Attachment) RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Job Fail. A printer job whose paper quantity exceeds Booklet Paper Quantity is canceled. (This
occurs with a job without simplex/duplex setting.)
This fault is detected at the start of print.
The number of sheets per set for printer print exceeds a specific allowable number for
Booklet.
–
If the number of sheets is larger by one, automatically only saddle stitching is dese-
lected and the sheets become folded in three for output.
–
If folding is only selected, an allowable number of sheets per set are automatically
folded for output.
Because the Print Service operation of setting simplex/duplex is done by Driver, only the
operation without simplex/duplex setting is done by the machine.
As a detection of this Fail causes a job to be canceled, a message is only displayed indi-
cating the job is canceled.
Procedure
•
Choose creation of every Booklet using a maximum number of sheets, or deselect Book-
let.
•
When every Booklet is created using a maximum number of sheets, a specific signature is
laid out on top of each booklet consisting of the max number of sheets.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required